Abstract

Objective To report our single center experience in the treatment of fusiform aneurysms involving the intracranial vertebral arteries using reconstructive endovascular techniques.

Patients and methods The neurointerventional database of our institution was retrospectively reviewed from June 2010 to February 2013. Patients who underwent endovascular treatment of fusiform intracranial vertebral artery aneurysms using reconstructive techniques were included in the analysis. Clinical presentation, size, reconstructive technique used, procedural complication, and clinical and angiographic follow-ups were included in the analysis.

Results Nine patients, aged 41–76 years (mean 54.8 years), were included. Mean angiographic diameter of unruptured aneurysms was 8.4 mm (range 4–14) while ruptured aneurysms averaged 6 mm (range 5–7 ). Two patients (two women) presented with acute subarachnoid hemorrhage (SAH). One patient with a large partially thrombosed aneurysm was treated with stent reconstruction requiring deployment of two stents (no coiling). There was one asymptomatic procedural complication (non-flow limiting cervical vertebral dissection). All patients had good clinical outcomes (modified Rankin Scale score of 0 or ≤1) including the two patients that presented with SAH (Hunt and Hess grades 2 and 3). There were no late hemorrhages at a mean clinical follow-up of 12 months (6–24 months). Eight patients had angiographic follow-up (6–18 months, mean 10.5 months) and six demonstrated aneurysm occlusion with complete vessel reconstruction at the angiographic follow-up.

Conclusions The use of reconstructive techniques in the endovascular treatment of unruptured fusiform intracranial vertebral artery aneurysms is feasible, safe, and effective in the mid term. In patients presenting with SAH, however, the safety and effectiveness of these techniques remain unclear.

  • Aneurysm
  • Stent
  • Intervention
  • Coil

Statistics from Altmetric.com

Request Permissions

If you wish to reuse any or all of this article please use the link below which will take you to the Copyright Clearance Center’s RightsLink service. You will be able to get a quick price and instant permission to reuse the content in many different ways.