Article Text

Download PDFPDF
Original research
Sidewall cerebral aneurysms: effect of an outflow angle-assisted approach on diagnosis
  1. Ling-Jun Sun1,
  2. Yong-Dong Li1,
  3. Bao-Zhi Yang2,
  4. Ming-Hua Li1,
  5. Wu Wang1,
  6. Bin-Xian Gu1
  1. 1 Institute of Diagnostic and Interventional Radiology, Shanghai Jiao Tong University Affiliated Sixth People's Hospital, Shanghai, China
  2. 2 Department of Radiology, The First Hospital of Xianyang, Xianyang, Shaanxi Province, China
  1. Correspondence to Dr Yong-Dong Li and Bao-Zhi Yang, Institute of Diagnostic and Interventional Radiology, Shanghai Jiao Tong University Affiliated Sixth People's Hospital, No. 600, Yi Shan Road, Shanghai 200233, China; Department of Radiology, The First Hospital of Xianyang, Shaanxi Province, No-10, Bi Yuan Road, Xianyang, 712000, China; liydsh{at}163.com and yangbaozhi65{at}163.com

Abstract

Background The ability to diagnose sidewall cerebral aneurysms (SCAs) on an angle measurement basis may be useful in clinical practice. A study was undertaken to evaluate the effect of an outflow angle (OA)-assisted approach.

Methods MR angiography (MRA) images of 438 patients with suspected SCAs and other cerebrovascular diseases were separately evaluated using the subjective approach and the OA approach. The approaches were then exchanged for confirmation of unclear cases. An OA of ≥90° was considered to represent SCA positivity. The accuracy, sensitivity, and specificity of the OA-assisted approach were determined using patient-based, aneurysm-based, and size-based evaluations.

Results Digital subtraction angiography (DSA) detected 301 SCAs in 267 patients and no SCAs in 171. An OA of ≥90° was observed for 271 aneurysms in 244 patients (true positives); the OA approach misinterpreted OA as <90° for 29 aneurysms in 29 patients (false negatives) and missed one aneurysm. The subjective approach detected 309 SCAs in 273 patients. This approach misdiagnosed 10 patients (false positives) and missed two aneurysms in two patients (false negatives). The OA-assisted approach detected 300 SCAs in 267 patients and no SCAs in 171, overlooking one aneurysm. Patient-based evaluation yielded high accuracy, sensitivity, specificity, and positive and negative predictive values for the OA-assisted approach.

Conclusions The OA-assisted approach for SCA diagnosis effectively reduced the false-positive rate obtained with the subjective approach with high accuracy, sensitivity, and specificity, suggesting that MRA based on this approach can be a reliable alternative to DSA in SCA screening and diagnosis.

  • Aneurysm
  • Magnetic Resonance Angiography
  • Angiography

Statistics from Altmetric.com

Request Permissions

If you wish to reuse any or all of this article please use the link below which will take you to the Copyright Clearance Center’s RightsLink service. You will be able to get a quick price and instant permission to reuse the content in many different ways.

Footnotes

  • Contributors L-JS was responsible for collecting the data and writing the paper. Y-DL and B-ZY contributed to the experimental design. WW and B-XG contributed to the measurement of the outflow angles. M-HL, Y-DL and B-ZY contributed to reviewing DSA findings.

  • Funding Sponsored by the Interdisciplinary Program of Shanghai Jiao Tong University (project no.YG2015MS11).

  • Competing interests None declared.

  • Patient consent Obtained.

  • Ethics approval This study was approved by the ethics committee of Shanghai Jiao Tong University Affiliated Sixth People's Hospital.

  • Provenance and peer review Not commissioned; externally peer reviewed.

  • Data sharing statement The authors agree to share any data on request. Any data from this study are available by contacting the corresponding author.