TY - JOUR T1 - Periprocedural outcomes and early safety with the use of the Pipeline Flex Embolization Device with Shield Technology for unruptured intracranial aneurysms: preliminary results from a prospective clinical study JF - Journal of NeuroInterventional Surgery JO - J NeuroIntervent Surg DO - 10.1136/neurintsurg-2016-012896 SP - neurintsurg-2016-012896 AU - Mario Martínez-Galdámez AU - Saleh M Lamin AU - Konstantinos G Lagios AU - Thomas Liebig AU - Elisa F Ciceri AU - Rene Chapot AU - Luc Stockx AU - Swarupsinh Chavda AU - Christoph Kabbasch AU - Giuseppe Farago AU - Hannes Nordmeyer AU - Thierry Boulanger AU - Mariangela Piano AU - Edoardo P Boccardi Y1 - 2017/02/17 UR - http://jnis.bmj.com/content/early/2017/02/20/neurintsurg-2016-012896.abstract N2 - Background and purpose The Pipeline Embolization Device (PED) has become a routine first-line option for treatment of intracranial aneurysms (IAs). We assessed the early safety and technical success of a new version of PED, Pipeline Flex Embolization Device with Shield Technology (Pipeline Shield), which has the same design and configuration but has been modified to include a surface synthetic biocompatible polymer.Materials and methods The Pipeline Flex Embolization Device with Shield Technology (PFLEX) study is a prospective, single-arm, multicenter study for the treatment of unruptured IAs using Pipeline Shield. The primary study endpoints included the occurrence of major stroke in the territory supplied by the treated artery or neurologic death at 1 year post-procedure. Secondary endpoints included the rate of Pipeline Shield-related or procedure-related serious or non-serious adverse events. Analyses were conducted to evaluate early safety findings in the 30-day post-procedure period as well as technical procedural success outcomes.Results Fifty patients with 50 unruptured target IAs were enrolled. Mean aneurysm diameter was 8.82±6.15 mm. Thirty-eight aneurysms (76%) were small (<10 mm). Device deployment was technically successful with 98% of devices. Complete wall apposition was achieved immediately post-procedure in 48 cases (96%). No major strokes or neurologic deaths were reported in the 30-day post-procedure period.Conclusions The results of this first experience with the new Pipeline Flex corroborate the early safety of the device. Mid-term and long-term follow-up examinations will provide data on safety outcomes at the 6-month and 1-year follow-up periods.Clinical trial registration NCT02390037. ER -