Abstract E-092 Table 1

Summary of Treatments, Outcomes and Complications

Patient NoDyna CT used?#Coils usedTotal Coil LengthTotal procedural timeImmediate Post-procedure Angiographic resultComplicationsFollow-up imaging time (Months)Follow-up imaging findingsClinical follow-up time (Months)Resolution of symptoms at follow-up?
1N14198 cm217 minComplete occlusionNone28No residual fistula (CT)57Yes
2Y898 cm125 cmComplete OcclusionNone16No residual fistula (MRA)21Yes
3N8180 cm287 cmResidual FistulaNone5No residual fistula (MRA)42Yes
4N14192 cm337 cmComplete OcclusionYes (headache, nausea, diplopia)23No residual fistula
(MRA)
55Yes
5Y698 cm412 cmMinimal, slow residual fillingNone7Small residual fistula15Yes
6Y12243 cm215 cmSmall residual fistula (no anterior venous drainage)None3No residual fistula35Yes
7Y19232 cm213 cmComplete OcclusionNone6No residual fistula20No (Resolving)
8Y7111 cm81 cmComplete OcclusionNone15No residual fistula26Yes