Abstract

Recent developments in minimally invasive approach to cerebrovascular diseases include the placement of stents in arteries for treatment of aneurysms. Preliminary clinical observations and experimental studies have shown that intravascular stents traversing the orifice may lead to thrombosis and subsequent occlusion of the aneurysm. The alterations in vessel local hemodynamics due to the introduction of a stent are not yet well understood. We investigated changes in local hemodynamics resulting from stent implantation. Pulsatile flow patterns in an experimental flow appraratus were visualized using laser-induced fluorescence of rhodamine dye. The test cells were constructed in a rectangular shape to facilitate an undisturbed longitudinal view of flow patterns in parent vessel and aneurysm models with and without porous stents. Woven nitinol stents of various porosities (76%, 80%, 82%, and 85%) were investigated. The selected fluid dynamic similarity parameters (Reynolds and Womersley numbers) represented conditions usually found in high-flow, larger arteries in humans (such as the carotid artery) and low-flow, smaller arteries (such as the vertebral artery). The mean Reynolds number for the larger arteries was 180, with maximum/minimum values of 490/−30 and the Womersley number was 5.3. The mean Reynolds number for the smaller arteries was 90, with maximum/minimum values of 230/2, and the Womersley number was 2.7. For the larger arteries modeled, placement of a stent of the lowest porosity across the aneurysm orifice resulted in reduction of aneurysmal vortex speed and decreased interaction with parent vessel flow. For smaller arteries, a stent of the same porosity led to a substantial reduction of parent vessel/aneurysmal flow interaction and the appearance of a nonrecirculating crescent of fluid rich in rhodamine dye in the aneurysm dome. Our results can help explainin vivo thrombus formation within an aneurysm after placement of a stent that is compatible with local hemodynamics.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Institutional subscriptions

Similar content being viewed by others

References

  1. Aenis, M., a. P. Stancampiano, A. K. Wakhloo, and B. B. Lieber. Modeling of flow in a straight stented and nonstented side wall aneurysm model.J. Biomech. Eng. 1997, in press.

  2. Baker, J. K. Analysis of the turbulent plane wake using laser Doppler anemometry and laser induced fluorescence. Buffalo: State University of New York at Buffalo, M.S. Thesis, 1992.

    Google Scholar 

  3. Bannermann, R. M., G. B. Ingall, and C. J. Graf. The familiar occurrence of intracranial aneurysms.Neurology 20:283–292, 1970.

    Google Scholar 

  4. Chandran, K. B. Cardiovascular Biomechanics. New York: New York University Press, 1992.

    Google Scholar 

  5. Doyle, R. Stroke mortality in men ages 35 to 74.Sci. Am. 274:26, 1996.

    Article  PubMed  CAS  Google Scholar 

  6. Hartfield, R. J. Jr., S. D. Hollo, and J. C. McDaniel. Planar measurement technique for compressible flows using laser-induced iodine fluorescence.AIAA J. 31:483–490, 1993.

    Article  CAS  Google Scholar 

  7. Kassell, N. F., and J. C. Torner. Epidemiology of intracranial aneurysms.Int. Anesthesiol. Clin. 20:13–17, 1982.

    Article  PubMed  CAS  Google Scholar 

  8. Loehrke, R. I., and H. M. Nagib. Control of free-stream turbulence by mean of honeycombs: a balance between suppression and generation.J. Fluids Eng. 98:342–353, 1976.

    Google Scholar 

  9. Marks, M. P., M. D. Dake, G. K. Steinberg, A. M. Norbash, and B. Lane. Stent placement for arterial and venous cerebrovascular disease: preliminary clinical experience.Radiology 191:441–446, 1994.

    PubMed  CAS  Google Scholar 

  10. Palmaz, J. C. Intravascular stent: tissue-stent interactions and design considerations.Am. J. Roentgenol. 160:613–618, 1993.

    CAS  Google Scholar 

  11. Schultz-Grunow, F. Pulsating flow through pipes (original in German).Forschung 11:170–187, 1940 (English reference, NASA-TT-F-14881, 1973).

    Google Scholar 

  12. Serpenguzel, A., J. C. Swindal, R. K. Chang, and W. Acker. Two-dimensional imaging of sprays with fluorescence, lasing, and stimulated raman scattering.appl. Optics 31:3543–3551, 1992.

    Article  Google Scholar 

  13. Stephanoff, K. D., I. J. Sobey, and B. J. Bellhouse. On flow through furrowed channels. Part 2. Observed flow patterns.J. Fluid Mech. 96:27–32, 1980.

    Article  Google Scholar 

  14. Stettler, J. C., and A. K. M. Fazle Hussain. On transition of pulsatile pipe flow.J. Fluid Mech. 170:169–197, 1986.

    Article  Google Scholar 

  15. Tominaga, R., H. Harasaki, C. Sutton, H. Emoto, H. Kambic, and J. Hollman. Effects of stent design and serum cholesterol level on the restenosis rate in atherosclerotic rabbits.Am. Heart J. 128:1049–1058, 1993.

    Article  Google Scholar 

  16. Viñuela, F. North American experience in the embolization of intracranial aneurysms with GDC system. American Society of Neuroradiology, 30th Annual Meeting, St. Louis, MO, May 31–June 6, 1992.

  17. Wakhloo, A. K., F. Schellhammer, J. de Vries, J. Haberstroh, and M. Schumacher. Self-expanding and balloon-expandable stents in the treatment of carotid aneurysms: an experimental study in a canine model.Am. J. Neuroradiol. 15:493–502, 1994.

    PubMed  CAS  Google Scholar 

  18. Wakhloo, A. K., F. O. Tio, B. B. Lieber, F. Schellhammer, M. Graf, and L. N. Hopkins. Self expanding nitinol stents in canine vertebral arteries: hemodynamics and tissue response.Am. J. Neuroradiol. 16:1043–1051, 1995.

    PubMed  CAS  Google Scholar 

  19. Weir, B. Aneurysms Affecting the Nervous System. Baltimore: Williams & Wilkins, 1987. pp. 1–60.

    Google Scholar 

  20. Whitmore, R. L. Rheology of the Circulation. Oxford: Pergamon Press, 1968, pp. 93–133.

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Rights and permissions

Reprints and permissions

About this article

Cite this article

Lieber, B.B., Stancampiano, A.P. & Wakhloo, A.K. Alteration of hemodynamics in aneurysm models by stenting: Influence of stent porosity. Ann Biomed Eng 25, 460–469 (1997). https://doi.org/10.1007/BF02684187

Download citation

  • Received:

  • Revised:

  • Accepted:

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF02684187

Keywords

Navigation