O-030 Changes in Contrast Transit times on Digital Subtraction Angiography Post Pipeline Embolization Device Deployment
  1. A Alaraj1,
  2. A Hussein2,
  3. A Linninger1,
  4. F Charbel II2,
  5. C Hsu1,
  6. F Charbel2,
  7. V Aletich2
  1. 1Neurosurgery and Bioengenerring, University of Illinois at Chicago, Chicago, IL
  2. 2Neurosurgery, University of Illinois at Chicago, Chicago, IL

Abstract

Introduction Pipeline Embolization Devices (PED) has been introduced as a new method to treat aneurysms that are otherwise difficult to treat surgically or with endovascular means. It is postulated that hemodynamic changes occur post deployment which affect the distal vascular bed. In this paper we evaluated changes in the contrast transit times on angiography post PED implementations.

Methods Medical charts and digital subtraction angiographic (DSA) films for patients treated with PED were included. Only anterior circulations, un-ruptured aneurysms, located proximal to the internal carotid artery terminus were included. DSA images were analyzed using custom made software for the time-density relationship at baseline and compared to post PED implementation. All analysis was done over region of interest over the middle cerebral artery (M1 segment). Analysis included TT10% 100% (time needed for the contrast to change from 10% image intensity to 100), TT100%–10% (time needed for the contrast to change from 100% image intensity to 10%), and TT25% 25% (time needed for the contrast to change from 25% image intensity-up slope to 25%-down slope of the curve).

Results A total of 44 patients were included in this study. Analysis over the M1 segment showed a significant decrease in the TT10%–100% (2.79 to 2.24 seconds, P < 0.001) post PED. There was significant correlation (Pearson’s correlation) between the percentage change in TT100% 10% and the aneurysm size (r = 0.34, P = 0.02). There was a significant decrease in the TT25%–25% (7.07 to 6.41 seconds, P = 0.016) post PED (Figure 1). Moreover, there was significant correlation between the absolute or percent changes in TT25%–25% and the aneurysm size (P = 0.05; rho = 0.54 and 0.049; rho = 0.29 respectively) (Figure 1).

Conclusion Analysis shows that statistically significant hemodynamic changes do occur post PED deployment, as determined by differences in the contrast transit time post PED in the distal intracranial circulation. These hemodynamic changes might be more pronounced in large and giant aneurysms. The mechanism for this is not clear, yet hemodynamic changes affecting especially the vasculature distal of the PED might shed a light at the patho-physiology of the delayed parenchymal hemorrhage.

Disclosures A. Alaraj: 2; C; Codman. A. Hussein: None. A. Linninger: None. F. Charbel: None. C. Hsu: None. F. Charbel: None. V. Aletich: 2; C; Codman.

This is an Open Access article distributed in accordance with the Creative Commons Attribution Non Commercial (CC BY-NC 4.0) license, which permits others to distribute, remix, adapt, build upon this work noncommercially, and license their derivative works on different terms, provided the original work is properly cited and the use is non-commercial. See: http://creativecommons.org/licenses/by-nc/4.0/