Article Text

Download PDFPDF
Original research
High prevalence of intracranial aneurysms in patients with aortic dissection or aneurysm: feasibility of extended aorta CT angiography with involvement of intracranial arteries
  1. Dahye Lee1,
  2. Sung Jun Ahn1,
  3. Eun-Suk Cho1,
  4. Yong Bae Kim2,
  5. Suk-Won Song3,
  6. Woo Sang Jung1,
  7. Sang Hyun Suh1,4
  1. 1Department of Radiology, Gangnam Severance Hospital, Yonsei University, Seoul, Korea
  2. 2Department of Neurosurgery, Gangnam Severance Hospital, Yonsei University, Seoul, Korea
  3. 3Department of Cardiovascular Surgery, Gangnam Severance Hospital, Yonsei University College of Medicine, Seoul, Korea
  4. 4Severance Institute of Vascular and Metabolic Research, Yonsei University College of Medicine, Seoul, Korea
  1. Correspondence to Professor Sang Hyun Suh, Department of Radiology, Gangnam Severance Hospital, Yonsei University College of Medicine, 712 Eonjoo-ro, Gangnam-gu, Seoul 135-720, Korea; suhsh11{at}yuhs.ac

Abstract

Introduction Previous studies have suggested a higher prevalence of intracranial aneurysms (IAs) in patients with aortic aneurysms (AAs).

Objective To carry out a preliminary study to evaluate the prevalence of IAs in these patients and the diagnostic feasibility of extended aorta CT angiography (CTA), including intracranial arteries as well as the aorta.

Materials and methods We retrospectively reviewed all patients with a clinical diagnosis of AA or aortic dissection (AD) who had undergone aorta CTA as well as MR angiography, CTA, and/or DSA of the brain between 2009 and 2014. Since 2012, the extended aorta CTA protocol has been applied in these patients. Characteristics of IAs were classified with baseline clinical data. For quantitative and qualitative assessment by two independent raters, brain images obtained by extended aorta CTA and brain CTA were compared. The radiation dose of the two aorta protocols was compared.

Results The prevalence of IA was 22.2% (35/158). All IAs were detected by extended aorta CTA, except one small aneurysm (<3 mm). The mean vascular attenuation value between brain images showed no difference (p=0.83), but the contrast-to-noise ratio was significantly lower in extended aorta CTA (p<0.001). In qualitative assessment, the interobserver agreement was substantial (k=0.79). For the radiation dose, the dose–length product of the extended aorta CTA increased with increment of the scan range (p=0.048).

Conclusions With a high prevalence of IAs in patients with ADs or AAs, extended aorta CTA could be used to evaluate aorta disease and IA in a single session. However, further prospective studies are needed to prove efficacy and safety of the extended aorta CTA protocol in patients with AAs or ADs.

  • Aneurysm
  • CT Angiography

Statistics from Altmetric.com

Request Permissions

If you wish to reuse any or all of this article please use the link below which will take you to the Copyright Clearance Center’s RightsLink service. You will be able to get a quick price and instant permission to reuse the content in many different ways.