Responses

PDF
Case report
Stentriever thrombectomy with distal protection device for carotid free floating thrombus: a technical case report
Compose Response

Plain text

  • No HTML tags allowed.
  • Web page addresses and e-mail addresses turn into links automatically.
  • Lines and paragraphs break automatically.
Author Information
First or given name, e.g. 'Peter'.
Your last, or family, name, e.g. 'MacMoody'.
Your email address, e.g. higgs-boson@gmail.com
Your role and/or occupation, e.g. 'Orthopedic Surgeon'.
Your organization or institution (if applicable), e.g. 'Royal Free Hospital'.
Statement of Competing Interests

PLEASE NOTE:

  • Responses are moderated before posting and publication is at the absolute discretion of BMJ, however they are not peer-reviewed
  • Once published, you will not have the right to remove or edit your response. Removal or editing of responses is at BMJ's absolute discretion
  • If patients could recognise themselves, or anyone else could recognise a patient from your description, please obtain the patient's written consent to publication and send them to the editorial office before submitting your response [Patient consent forms]
  • By submitting this response you are agreeing to our full [Response terms and requirements]

Vertical Tabs

Other responses

Jump to comment:

  • Published on:
    Aspiration with distal filter protection: an effective management for carotid floating thrombus
    • Biplab Das, Neurointervention Medanta The Medicity, Gurgaon, India
    • Other Contributors:
      • Gaurav Goel, Neurointervention
      • Anshu Mahajan, Neurointervention
      • Arun Garg, Neurology
      • Harsh Sapra, Neuroanaesthesia

    To the editor,

    Giragani S et al. (published online 25 January 2017) described a remarkable case of recurrent transient ischemic attacks (TIA) due to carotid free floating thrombus. They successfully used stentriever with distal filter protection in retrieving the thrombus.

    Here we share a similar case of TIA with right common carotid artery (CCA) floating thrombus that was effectively managed with distal filter protection and aspiration. A 48-year-male with recurrent ischemic symptoms detected to have right CCA long segment floating thrombus (approximately 4.5 cm) extending upto right proximal external carotid artery.* Under general anaesthesia through right femoral route long sheath guiding catheter (Neuron Max 6F088; Penumbra, Inc. Alameda, USA) was placed in right proximal CCA. After parking the filter device (Spider FX 6mm; eV3, Plymouth, Minnesota, USA) at distal cervical segment, thrombus was aspirated using penumbra system (5MAX ACE, 132 cm; Penumbra, Inc. Alameda, USA).* Final check angiography showed 80 % reduction in clot burden .*

    Placing the filter protection device in the distal cervical segment does not protect thrombus migration to ECA, although it primarily prevent intracranial shower. In our index case thrombus fragment migrated to ECA, although it did not cause any neurological deficit. These cases highlight a novel technique to treat free floating thrombus.

    *Representative image available.