PT - JOURNAL ARTICLE AU - Martínez-Galdámez, Mario AU - Biondi, Alessandra AU - Kalousek, Vladimir AU - Pereira, Vitor M AU - Ianucci, Giuseppe AU - Gentric, Jean-Christophe AU - Mosimann, Pascal J AU - Brisbois, Denis AU - Schob, Stefan AU - Quäschling, Ulf AU - Kaesmacher, Johannes AU - Ognard, Julien AU - Escartín, Jorge AU - Tsang, Chun On Anderson AU - Čulo, Branimir AU - Chabert, Emmanuel AU - Turjman, Francis AU - Barbier, Charlotte AU - Mihalea, Cristian AU - Spelle, Laurent AU - Chapot, René TI - Periprocedural safety and technical outcomes of the new Silk Vista Baby flow diverter for the treatment of intracranial aneurysms: results from a multicenter experience AID - 10.1136/neurintsurg-2019-014770 DP - 2019 Jul 01 TA - Journal of NeuroInterventional Surgery PG - 723--727 VI - 11 IP - 7 4099 - http://jnis.bmj.com/content/11/7/723.short 4100 - http://jnis.bmj.com/content/11/7/723.full SO - J NeuroIntervent Surg2019 Jul 01; 11 AB - Purpose The aim of our study was to assess the technical success and the safety of this new low-profile flow diverter Silk Vista Baby (SVB) by evaluating the intraprocedural and periprocedural complication rate.Material/methods Clinical, procedural, and angiographic data were analyzed.Results: 41 consecutive patients (28 women; age average 50.5 years) with 43 aneurysms were treated with SVB. Aneurysm sizes were classified by their maximum diameter, with an average size of 9.5 mm (range 2–30 mm). Thirty-four cases were unruptured. five aneurysms previously ruptured, had recurrence after the initial coiling. There were two ruptured cases. Aneurysms' locations were: M1 segment (five cases), M2 segment (three cases), M3 segment (one case), middle cerebral artery (MCA) bifurcation (six cases), carotid-T (two cases), anterior communicating artery/A1/A2 (11 cases), pericallosal artery (four cases), supraclinoid ICA (two cases), PCom (one case), V4 segment (three cases), PCA (three cases), SCA (one case), and PICA (one case). We had five intraprocedural complications which resolved without clinical consequences and three events postprocedural events. Initial occlusion rates were: eight aneurysms (18.6%) were completely occluded, five aneurysms (11.6%) showed near-complete occlusion, four cases (9.3%) showed incomplete filling, and 26 cases (60.4%) showed persisting filling. The mRS score at discharge from the hospital did not change from the admission mRS score.Conclusion Our study demonstrated that the use of the new low-profile flow diverter, SVB device, for the treatment of intracranial aneurysms is feasible and technically safe.