Table 2

Procedural details

CaseMicrocatheter usedTip detachedVolume of PHIL used (mL)Duration (h:min:s)Screening time (min)Radiation dose (μGy m2)
1Apollo 5 cmYes<300:46:0039.76407.9
2MarathonNot applicable<100:28:4115.612691.8
3Scepter CNot applicable<401:20:257818949.2
4Apollo 3 cmYes<101:41:4849.738070.8
5Apollo 5 cmYes<300:40:2628.611277.1
6MarathonNot applicable<101:16:3635.729802.4
7Apollo 3 cmYes<201:26:513930637.6
8Apollo 3 cmYes<200:27:0118.98063.6
  • PHIL, Precipitating Hydrophobic Injectable Liquid.