Table 4

Multivariable logistic regression model for achieving mRS score ≤2 at discharge

VariableOR95% CIp Value
Anesthesia type*0.048
 Volatilereference
 TIVA0.690.13 to 3.77
 MAC0.350.04 to 3.76
 Comb0.150.04 to 0.66
Age0.960.93 to 0.990.044
NIHSS0.870.79 to 0.960.010
  • *Reference category for anesthesia type is volatile. Thus, ORs for the other anesthesia types are in reference to volatile anesthesia.

  • Comb, combined intravenous and volatile anesthesia; MAC, monitored anesthesia care; mRS, modified Rankin Scale; NIHSS, NIH Stroke Scale; TIVA, total intravenous anesthesia.