Table 2

Status of VOL before and after venous sinus stenting

Status of VOLTotal (%)*No SASSASp Value
Immediately after stent placement (n=32 evaluable patients)
 Normal filling24 (75.0)17 (73.9)7 (77.8)0.8312
 Diminished caliber with normal transit time1 (3.1)1 (4.3)0
 Sluggish flow6 (18.8)4 (17.4)2 (22.2)
 Occluded1 (3.1)1 (4.3)0
At follow-up angiography (n=46 evaluable patients)
 Normal filling33 (71.7)27 (73.0)6 (66.7)0.711
 Diminished caliber with normal transit time12 (26.1)9 (24.3)3 (33.3)
 Sluggish flow1 (2.2)1 (2.7)0
 Occluded000
  • *Values reflect number of stents placed. In one patient, bilateral transverse–sigmoid sinus stents were placed and the assessment of VOL patency was made separately for each side.

  • SAS, stent-adjacent stenosis; VOL, vein of Labbé.