Author | Presenting symptoms | Improvement In symptoms post-stent | Major complication | Need of second procedure | Subsequent endovascular | Subsequent CSF diversion | Mean CSF pressure post-tenting (min–max) | ||||
HA | PA | PT | HA | PA | PT | ||||||
Higgins et al 13 2003 | 12 | 8 | NR | 7 | 5 | NR | 0 | 2 | 2 | 0 | NR |
Donnet et al 12 2008 | 10 | 10 | 5 | 8 | 10 | 5 | 0 | 1 | 1 | 0 | 14 (9–19) |
Bussière et al 11 2010 | 10 | 10 | 3 | 10 | 10 | NR | 0 | 0 | 0 | 0 | NR |
Ahmed et al 8 2011 | 43 | 45 | 17 | 35 | 45 | 17 | 2 (SDH) | 6 | 6 | 0 | 22 (12–39)* |
Albuquerque et al 14 2011 | 15 | NR | NR | 12 | NR | NR | 0 | 0 | 0 | 0 | NR |
Fields et al 16 2013 | 15 | 15 | 14 | 10 | 15 | 11 | 0 | 1 | 0 | 1 | NR |
Ducruet et al 15 2014 | 30 | 30 | NR | 19 | 30 | NR | 0 | 5 | 0 | 5 | NR |
Goodwin et al 21 2014 | 15 | 13 | 13 | 12 | 13 | 13 | 0 | 3 | 0 | 3 | NR |
Teleb et al 22 2015 | 18 | 18 | 5 | 10 | 18 | 4 | 0 | 6 | 6 | 0 | NR |
Liu et al 23* 2016 | 10 | 7 | 5 | 9 | 7 | NR | 0 | 2 | 2 | 0 | NR |
Boddu et al 10 PLOS 2016 | 29 | 13 | 29 | NR | NR | 28 | 0 | 2 | 0 | 0 | NR |
Kumpe et al 17 18 2012 −2016 | 31 | 37 | NR | 23 | 33 | NR | 2 (SDH, SAH) | 8 | 8 | 0 | NR |
Aguillar-Pérez et al 24 2017 | 37 | 50 | 9 | 31 | 42 | 9 | 0 | 8 | 8 | 0 | NR |
Satti et al 25 2017 | 43 | 22 | NR | 27 | 13 | NR | 0 | 2 | 2 | 0 | NR |
Shazly et al 26 2017 | NR | 6 | NR | NR | 6 | NR | 0 | 0 | 0 | 0 | NR |
Silva et al 27 2017 | 6 | 6 | NR | 6 | 5 | NR | 0 | 0 | 0 | 0 | 26 (23–27) |
Smith et al 28 2017 | 17 | 11 | 8 | 15 | 9 | 3 | 0 | 2 | 2 | 0 | 22 (12–34)† |
Lenck et al 19 2017 | 20 | 21 | 14 | 19 | 21 | 14 | 0 | 0 | 0 | 0 | NR |
Asif et al 9 2017 | 41 | 30 | 21 | 26 | 24 | 12 | 0 | 3 | 3 | 0 | NR |
El Mekabaty et al
29 2017 | 31 | 31 | 19 | 23 | 30 | 18 | 0 | 8 | 1 | 7 | NR |
Totals | 433 | 383 | 162 | 302 | 336 | 134 | 4 | 59 | 41 | 16 | 21 |
*CSF opening pressure only measured following stenting in four of 37 patients who had pre-stent pressure measurements.
†CSF opening pressure only measured following stenting in nine of 17 patients who had pre-stent pressure measurements.
HA: headache, PA: papilledema, PT: pulsatile tinnitus, SDH: subdural hematoma, SAH: subarachnoid hemorrhage.