Article Text

Download PDFPDF
Endovascular therapy of carotid artery stenosis: a prospective case study
  1. D Claus1,
  2. P Huppert2,
  3. R Bauersachs3,
  4. H Diegel1,
  5. G Hedtmann1
  1. 1Department of Neurology, Klinikum Darmstadt, Darmstadt, Germany
  2. 2Institute for Diagnostic and Interventional Radiology, Klinikum Darmstadt, Darmstadt, Germany
  3. 3Department of Angiology, Klinikum Darmstadt, Darmstadt, Germany
  1. Correspondence to Professor D Claus, Department of Neurology, Klinikum Darmstadt, Heidelberger Landstr 379, Darmstadt D-64297, Germany; d.claus{at}t-online.de

Abstract

Carotid artery stenting was carried out in a prospective consecutive case study. All interventions were done by the same investigator (PH), and one type of stenting device was used. Additionally, periprocedural monitoring was carried out for at least 24 h. 190 patients were included (70±8.9 years). All had a high grade stenosis (>70% according to North American Symptomatic Carotid Endarterectomy Trial (NASCET) criteria). 140 were men and 50 were women. 104 (55%) had symptomatic stenosis and 86 (45%) had asymptomatic stenosis. A self-expanding nitinol–carotis stent was used (Cordis Precise stent; Johnson and Johnson) with an emboli capture guidewire basket system (Angioguard; Cordis). 30 day complications (infarct, hemorrhage, death due to either) were seen in 13 cases (6.8%). Disabling complications with an increase in the modified Rankin Scale by >2 points after 6 months were seen in five cases (2.6%). The rate of complications after carotid artery stenting was comparable with that after carotid endarterectomy (from the literature). No correlation was seen between complications and age, gender, diabetes, hypertension, symptomatic stenosis or plaque morphology. This may be because of the the 24 h post-procedural monitoring.

  • Brain
  • Stenosis
  • Stroke
  • Intervention
  • Stent

Statistics from Altmetric.com

Request Permissions

If you wish to reuse any or all of this article please use the link below which will take you to the Copyright Clearance Center’s RightsLink service. You will be able to get a quick price and instant permission to reuse the content in many different ways.

Footnotes

  • Linked article 001677.

  • Competing interests None.

  • Ethics approval This study was conducted with the approval of the Ärztekammer Hessen. All human studies were reviewed by the appropriate ethics committee and have therefore been performed in accordance with the ethical standards laid down in the 1964 Declaration of Helsinki.

  • Patient consent Obtained.

  • Provenance and peer review Not commissioned; externally peer reviewed.

Linked Articles