Skip to main content
Log in

Follow-up of intracranial aneurysms treated with detachable coils: comparison of plain radiographs, 3D time-of-flight MRA and digital subtraction angiography

  • Interventional Neuroradiology
  • Published:
Neuroradiology Aims and scope Submit manuscript

Abstract

All patients with aneurysms treated with Guglielmi detachable coils (GDC) are undergo angiography to assess long-term stability of aneurysm exclusion or to show recurrence of the aneurysm sac, which may require further treatment. We prospectively compared the plain-film appearance of the coil-mass, 3D time-of-flight MR angiography (TOF MRA) and digital subtraction angiography (DSA) for the detection of aneurysm recanalisation during follow-up. We studied 60  patients with 74 intracranial aneurysms treated with Guglielmi detachable coils. We used the unsubtracted image of the angiograms performed at the completion of any embolisation procedure and at follow-up as the plain radiographs. Recanalisation was considered if loosening, compaction or reorientation of the coil mass was apparent. TOF MRA was performed to assess the presence and size of a neck remnant. DSA was regarded as the definitive investigation. Comparison of the techniques showed good agreement as regards aneurysm recanalisation. MRA was more accurate than plain radiography and could replace DSA for long term follow- up. The initial follow-up examination should, however, include both modalities. In cases of contraindications or limitations to MRA, the interval between follow-up angiographic examinations could be increased if there is no change in the plain-film coil-mass appearances.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Institutional subscriptions

Fig. 1a–f
Fig. 2a–f

Similar content being viewed by others

References

  1. Guglielmi G, Viñuela F, Dion J, Duckwiler G (1991) Electrothrombosis of saccular aneurysms via endovascular approach. I: preliminary clinical experience. J Neurosurg 75: 8–14

    CAS  PubMed  Google Scholar 

  2. Derdeyn CP, Graves VB, Tursky PA, Masaryk AM, Strother CM (1997) MR angiography of saccular aneurysms after treatment with Guglielmi detachable coils: preliminary experience. AJNR 18: 279–286

    CAS  Google Scholar 

  3. Gönner F, Heid L, Remonda G, et al (1998 ) MR angiography with ultrashort echo time in cerebral aneurysms treated with Guglielmi detachable coils. AJNR 19: 1324–1328

    Google Scholar 

  4. Kähära VJ, Seppänen SK, Ryymin PS, Mattila P, Kuurne T, Laasonen EM (1999) MR angiography with three-dimensional time-of-flight and targeted maximum-intensity-projection reconstructions in the follow-up of intracranial aneurysms embolized with Guglielmi detachable coils. AJNR 20: 1470 –1475

    Google Scholar 

  5. Brunereau L, Cottier JP, Sonier CB, et al (1999) Prospective evaluation of time-of-flight MR angiography in the follow-up of intracranial saccular aneurysms treated with Guglielmi detachable coils. J Comput Assist Tomogr 23: 216–223

    Article  CAS  PubMed  Google Scholar 

  6. Anzalone N, Righi C, Simionato F, et al (2000) Three-dimensional time-of-flight MR angiography in the evaluation of intracranial aneurysms treated with Guglielmi detachable coils. AJNR 21: 746 –752

    CAS  Google Scholar 

  7. Boulin A, Pierot L (2000) Follow-up of intracranial aneurysms treated with detachable coils: comparison of gadolinium enhanced 3D time-of-flight MR angiography and digital subtraction angiography. Radiology 219: 108–113

    Google Scholar 

  8. Nome T, Bakke SJ, Nakstad PH (2002) MR angiography in the follow-up of coiled cerebral aneurysms after treatment with Guglielmi detachable coils. Acta Radiol 43: 10–14

    Article  PubMed  Google Scholar 

  9. Leclerc X, Navez JF, Gauvrit JY, Lejeune JP, Pruvo JP (2001) Aneurysms of the anterior communicating artery treated with Guglielmi detachable coils: follow-up with contrast-enhanced MR angiography. AJNR 23: 112–1127

    Google Scholar 

  10. Connor SEJ, West RJ, Yates DA (2001) The ability of plain radiography to predict intracranial aneurysm occlusion instability during follow-up of endosaccular treatment with Guglielmi detachable coils. Neuroradiology 43: 680–686

    Article  CAS  PubMed  Google Scholar 

  11. Cognard C, Weill A, Spelle L, et al (1999) Long-term angiographic follow-up of 169 intracranial berry aneurysms occluded with detachable coils. Radiology 212: 348–356

    CAS  PubMed  Google Scholar 

  12. Viñuela F, Duckwiler G, Mawad M, Guglielmi G (1997) Detachable coil embolisation of acute intracranial aneurysm: perioperative anatomical and clinical outcome in 403 patients. J Neurosurg 86: 475–482

    PubMed  Google Scholar 

  13. Byrne JV, Sohn MJ, Molyneux AJ (1999) Five-year experience in using coil embolisation for ruptured intracranial aneurysms: outcomes and incidence of late rebleeding. J Neurosurg 90: 656–663

    CAS  PubMed  Google Scholar 

  14. Cloft HJ, Joseph GJ, Dion JE (1999) Risk of cerebral angiography in patients with subarachnoid hemorrhage, cerebral aneurysm, and arteriovenous malformation. a meta-analysis. Stroke 30: 317–320

    CAS  PubMed  Google Scholar 

  15. Heiserman JE, Dean BL, Hodak JA, et al (1994) Neurologic complications of cerebral angiography. AJNR 15: 1408–1411

    Google Scholar 

  16. Hartman J, Nguyen T, Larsen D, Teitelbaum GP (1997) MR artifacts, heat production, and ferromagnetism of Guglielmi detachable coils: preliminary experience. AJNR 18: 279–286

    CAS  Google Scholar 

  17. Piotin M, Mandai S, Murphy KJ, et al (2000) Dense packing of cerebral aneurysms: an in vitro study with detachable platinum coils. AJNR 21: 757–760

    CAS  Google Scholar 

  18. Reul J, Spetzger U, Weis J, Sure U, Gilsbach JM, Thron A (1997) Endovascular occlusion of experimental aneurysms with detachable coils: influence of packing density and perioperative anticoagulation. Neurosurgery 41: 1160–1165

    CAS  PubMed  Google Scholar 

  19. Byrne JV, Hope JKA, Hubbard N, Morris JH (1997) The nature of thrombosis induced by platinum and tungsten coils in saccular aneurysms. AJNR 18: 29–33

    CAS  Google Scholar 

  20. Cognard C, Weill A, Castaing L, et al (1998) Intracranial berry aneurysms: angiographic and clinical results after endovascular treatment. Radiology 206: 499–510

    CAS  PubMed  Google Scholar 

  21. Feuerberg I, Lindquist C, Lindqvist M, et al (1987) Natural history of postoperative aneurysm rests. J Neurosurg 66: 30–34

    CAS  PubMed  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to J. P. Cottier.

Rights and permissions

Reprints and permissions

About this article

Cite this article

Cottier, J.P., Bleuzen-Couthon, A., Gallas, S. et al. Follow-up of intracranial aneurysms treated with detachable coils: comparison of plain radiographs, 3D time-of-flight MRA and digital subtraction angiography. Neuroradiology 45, 818–824 (2003). https://doi.org/10.1007/s00234-003-1109-7

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s00234-003-1109-7

Key words

Navigation