Abstract
Objectives
To prospectively assess coiled intracranial aneurysms using a novel non-contrast enhanced zero echo time (zTE) MR angiography (MRA) method, and compare its image quality with time-of-flight (TOF) MRA, using digital subtraction angiography (DSA) as reference.
Methods
Twenty-five patients (10 males and 15 females; age 53.96 ± 12.46 years) were enrolled in this monocentric study. MRA sequences were performed 24 h before DSA. Susceptibility artefact intensity and flow signal within the parent artery were carried out using a 4-point scale. Occlusion status was assessed using the 3-grade Montreal scale.
Results
Scores of zTE were higher than TOF for both susceptibility artefact intensity (3.42 ± 0.64, 2.92 ± 0.63, P = 0.01) and flow signal (3.66 ± 0.95, 3.24 ± 1.24, P = 0.01). DSA revealed 17 complete occlusions, five residual neck aneurysms and two residual aneurysms. Inter-observer agreement was excellent (weighted κ: 0.89) for zTE and good (weighted κ: 0.68) for TOF. Intermodality agreement was excellent for zTE (weighted κ: 0.95) and good for TOF (weighted κ: 0.80). Correlations of both MRA sequences with DSA were high (zTE, Spearman’s ρ: 0.91; TOF, Spearman’s ρ: 0.81).
Conclusions
zTE MRA showed promising results for follow-up assessment of coiled intracranial aneurysms and was superior to TOF MRA for visualizing the parent artery and evaluating occlusion status.
Key Points
• Various MRA sequences were applied for follow-up assessment of coiled intracranial aneurysms.
• zTE MRA was less sensitive to susceptibility artefacts and haemodynamics.
• In this monocentric study, zTE MRA was equivalent to DSA.
• zTE MRA maybe an alternative to TOF MRA for follow-up assessment.
Similar content being viewed by others
Abbreviations
- ACA:
-
Anterior cerebral artery
- ACoA:
-
Anterior communicating artery
- ASL:
-
Arterial spin labelling
- CE:
-
Contrast-enhanced
- CI:
-
Confidence interval
- DSA:
-
Digital subtraction angiography
- F:
-
Females
- FOV:
-
Field of view
- M:
-
Males
- m:
-
Months
- MIP:
-
Maximum intensity projection
- MRA:
-
Magnetic resonance angiography
- NEX:
-
Number of excitations
- PCoA:
-
Posterior communicating artery
- r:
-
Spearman’s correlation coefficient
- TE:
-
Echo time
- TOF:
-
Time of flight
- TR:
-
Repetition time
- VR:
-
Volume renderings
- zTE:
-
Zero echo time
- κ:
-
Weighted kappa value
References
Molyneux AJ, Kerr RS, Yu LM et al (2005) International subarachnoid aneurysm trial (ISAT) of neurosurgical clipping versus endovascular coiling in 2143 patients with ruptured intracranial aneurysms: a randomised comparison of effects on survival, dependency, seizures, rebleeding, subgroups, and aneurysm occlusion. Lancet 366:809–817
Jalbert JJ, Isaacs AJ, Kamel H et al (2015) Clipping and coiling of unruptured intracranial aneurysms among medicare beneficiaries, 2000 to 2010. Stroke 46:2452–2457
Binning MJ, Veznedaroglu E (2015) Aneurysm remnants after coiling and clipping: considerations in surgical and endovascular treatment options. Neurosurgery 62:103–106
Ferns SP, Sprengers ME, van Rooij WJ et al (2009) Coiling of intracranial aneurysms: a systematic review on initial occlusion and reopening and retreatment rates. Stroke 40:e523–e529
van Eijck M, Bechan RS, Sluzewski M et al (2015) Clinical and imaging follow-up of patients with coiled basilar tip aneurysms up to 20 years. AJNR Am J Neuroradiol 36:2108–2113
Serafin Z, Strzesniewski P, Lasek W et al (2012) Comparison of remnant size in embolized intracranial aneurysms measured at follow-up with DSA and MRA. Neuroradiology 54:1381–1388
van Amerongen MJ, Boogaarts HD, de Vries J et al (2014) MRA versus DSA for follow-up of coiled intracranial aneurysms: a meta-analysis. AJNR Am J Neuroradiol 35:1655–1661
Attali J, Benaissa A, Soize S et al (2014) Follow-up of intracranial aneurysms treated by flow diverter: comparison of three-dimensional time-of-flight MR angiography (3D-TOF-MRA) and contrast-enhanced MR angiography (CE-MRA) sequences with digital subtraction angiography as the gold standard. J Neurointerv Surg
Schaafsma JD, Koffijberg H, Buskens E et al (2010) Cost-effectiveness of magnetic resonance angiography versus intra-arterial digital subtraction angiography to follow-up patients with coiled intracranial aneurysms. Stroke 41:1736–1742
Mine B, Tancredi I, Aljishi A et al (2015) Follow-up of intracranial aneurysms treated by a WEB flow disrupter: a comparative study of DSA and contrast-enhanced MR angiography. J Neurointerv Surg
Agid R, Willinsky RA, Lee SK et al (2008) Characterization of aneurysm remnants after endovascular treatment: contrast-enhanced MR angiography versus catheter digital subtraction angiography. AJNR Am J Neuroradiol 29:1570–1574
Cho WS, Kim SS, Lee SJ et al (2014) The effectiveness of 3T time-of-flight magnetic resonance angiography for follow-up evaluations after the stent-assisted coil embolization of cerebral aneurysms. Acta Radiol 55:604–613
Walker MT, Tsai J, Parish T et al (2005) MR angiographic evaluation of platinum coil packs at 1.5T and 3T: an in vitro assessment of artifact production: technical note. AJNR Am J Neuroradiol 26:848–853
Kakeda S, Korogi Y, Hiai Y et al (2008) MRA of intracranial aneurysms embolized with platinum coils: a vascular phantom study at 1.5T and 3T. J Magn Reson Imaging 28:13–20
Kuo PH, Kanal E, Abu-Alfa AK et al (2007) Gadolinium-based MR contrast agents and nephrogenic systemic fibrosis. Radiology 242:647–649
Robson PM, Dai W, Shankaranarayanan A et al (2010) Time-resolved vessel-selective digital subtraction MR angiography of the cerebral vasculature with arterial spin labeling. Radiology 257:507–515
Wu H, Block WF, Turski PA et al (2013) Noncontrast-enhanced three-dimensional (3D) intracranial MR angiography using pseudocontinuous arterial spin labeling and accelerated 3D radial acquisition. Magn Reson Med 69:708–715
Koktzoglou I, Meyer JR, Ankenbrandt WJ et al (2015) Nonenhanced arterial spin labeled carotid MR angiography using three-dimensional radial balanced steady-state free precession imaging. J Magn Reson Imaging 41:1150–1156
Weiger M, Brunner DO, Dietrich BE et al (2013) ZTE imaging in humans. Magn Reson Med 70:328–332
Alibek S, Vogel M, Sun W et al (2014) Acoustic noise reduction in MRI using silent scan: an initial experience. Diagn Interv Radiol 20:360–363
Irie R, Suzuki M, Yamamoto M et al (2015) Assessing blood flow in an intracranial stent: a feasibility study of mr angiography using a silent scan after stent-assisted coil embolization for anterior circulation aneurysms. AJNR Am J Neuroradiol 36:967–970
Raymond J, Guilbert F, Weill A et al (2003) Long-term angiographic recurrences after selective endovascular treatment of aneurysms with detachable coils. Stroke 34:1398–1403
Pierot L, Portefaix C, Gauvrit JY et al (2012) Follow-up of coiled intracranial aneurysms: comparison of 3D time-of-flight MR angiography at 3T and 1.5T in a large prospective series. AJNR Am J Neuroradiol 33:2162–2166
Schaafsma JD, Velthuis BK, Vincken KL et al (2014) Artefacts induced by coiled intracranial aneurysms on 3.0-Tesla versus 1.5-Tesla MR angiography--an in vivo and in vitro study. Eur J Radiol 83:811–816
Zhuo J, Gullapalli RP (2006) AAPM/RSNA physics tutorial for residents: MR artifacts, safety, and quality control. Radiographics 26:275–297
Dai W, Garcia D, de Bazelaire C et al (2008) Continuous flow-driven inversion for arterial spin labeling using pulsed radio frequency and gradient fields. Magn Reson Med 60:1488–1497
Kaufmann TJ, Huston J 3rd, Cloft HJ et al (2010) A prospective trial of 3T and 1.5T time-of-flight and contrast-enhanced MR angiography in the follow-up of coiled intracranial aneurysms. AJNR Am J Neuroradiol 31:912–918
Levent A, Yuce I, Eren S et al (2014) Contrast-enhanced and time-of-flight MR angiographic assessment of endovascular coiled intracranial aneurysms at 1.5 T. Interv Neuroradiol 20:686–692
Kanda T, Fukusato T, Matsuda M et al (2015) Gadolinium-based contrast agent accumulates in the brain even in subjects without severe renal dysfunction: evaluation of autopsy brain specimens with inductively coupled plasma mass spectroscopy. Radiology 276:228–232
McDonald RJ, McDonald JS, Kallmes DF et al (2015) Intracranial gadolinium deposition after contrast-enhanced MR imaging. Radiology 275:772–782
Choi JW, Roh HG, Moon WJ et al (2011) Optimization of MR parameters of 3D TOFpRA for various intracranial stents at 3.0T MRI. Neurointervention 6:71–77
Lettau M, Sauer A, Heiland S et al (2009) Carotid artery stents: in vitro comparison of different stent designs and sizes using CT angiography and contrast-enhanced MR angiography at 1.5T and 3T. AJNR Am J Neuroradiol 30:1993–1997
Wong SC, Nawawi O, Ramli N et al (2012) Benefits of 3D rotational DSA compared with 2D DSA in the evaluation of intracranial aneurysm. Acad Radiol 19:701–707
Wallace RC, Karis JP, Partovi S et al (2007) Noninvasive imaging of treated cerebral aneurysms, part I: MR angiographic follow-up of coiled aneurysms. AJNR Am J Neuroradiol 28:1001–1008
Pierot L, Portefaix C, Boulin A et al (2012) Follow-up of coiled intracranial aneurysms: comparison of 3D time-of-flight and contrast-enhanced magnetic resonance angiography at 3T in a large, prospective series. Eur Radiol 22:2255–2263
Author information
Authors and Affiliations
Corresponding author
Ethics declarations
Guarantor
The scientific guarantor of this publication is Jingtao Wu.
Conflict of interest
The authors of this manuscript declare no relationships with any companies whose products or services may be related to the subject matter of the article.
Funding
This study received funding from the National Natural Science Foundation of China (NSFC 81571652).
Statistics and biometry
No complex statistical methods were necessary for this paper.
Ethical approval
Institutional Review Board approval was obtained.
Informed consent
Written informed consent was obtained from all subjects (patients) in this study.
Methodology
• prospective
• diagnostic or prognostic study
• performed at one institution
Rights and permissions
About this article
Cite this article
Shang, S., Ye, J., Luo, X. et al. Follow-up assessment of coiled intracranial aneurysms using zTE MRA as compared with TOF MRA: a preliminary image quality study. Eur Radiol 27, 4271–4280 (2017). https://doi.org/10.1007/s00330-017-4794-z
Received:
Revised:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s00330-017-4794-z