Skip to main content
Log in

Embolization of wide-necked aneurysms with using three or more microcatheters

  • Clinical Article
  • Published:
Acta Neurochirurgica Aims and scope Submit manuscript

Summary

Background. A new and relatively simple endovascular technique, in which more than three microcatheters are used for endovascular treatment of cerebral aneurysms for the first time, is described.

Method. Eight patients with wide necked aneurysms were successfully treated with detachable coils using the multiple microcatheter technique. Three patients presented with subarachnoid haemorrhage and five were unruptured. The aneurysm locations were superior hypophyseal artery (2), posterior communicating artery (2), middle cerebral artery bifurcation (1), distal anterior cerebral artery (1), basilar artery (1) and vertebral artery (1). The average neck size was 7.4 ± 2.8 mm (3.5–12 mm), average width of the aneurysms was 10.6 ± 5.7 mm (6.2–23 mm) and depth was 8.9 ± 5.8 mm (3–22 mm). Three microcatheters (7 patients) and four microcatheters (1 patient) were introduced and used for coil delivery. Three or four coils were deployed and intermingled to stabilize the whole coil mass as well as to occupy the aneurysmal sac. When a relatively stable coil frame was formed, one coil was detached and subsequent coils were inserted. After the coil mass became more stable, other coils were also detached and all microcatheters were used for subsequent coil deployment.

Findings. All aneurysms were successfully treated without complications. Postemboilzation angiograms showed no contrast filling in 5 cases (100% occlusion) and a very small residual neck in 3 cases. There was no procedure related complication.

Conclusion. The multiple microcatheter technique can be one technical option for the endovascular treatment of wide necked aneurysms.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Institutional subscriptions

Similar content being viewed by others

References

  • OK Kwon SH Kim BJ Kwon HS Kang JH Kim CW Oh MH Han (2005) ArticleTitleEndovascular treatment of wide-necked aneurysms using two microcatheters: techniques and outcomes in twenty-five patients AJNR 26 894–900 Occurrence Handle15814940

    PubMed  Google Scholar 

  • LP Widebent CJ Moran W De T Cross SuffixIII CP Derdeyn (2003) ArticleTitleManagement of neuroform stent dislodgement and misplacement AJNR 24 1819–1822

    Google Scholar 

  • G Lanzino AK Wakhloo RD Fessler ML Hartney LR Guterman LN Hopkins (1999) ArticleTitleEfficacy and current limitations of intravascular stents for intracranial internal carotid, vertebral, and basilar artery aneurysms J Neurosurg 91 538–546 Occurrence Handle10507372 Occurrence Handle1:STN:280:DyaK1MvjsFajtA%3D%3D Occurrence Handle10.3171/jns.1999.91.4.0538

    Article  PubMed  CAS  Google Scholar 

  • DI Levy A Ku (1997) ArticleTitleBalloon-assisted coil placement in wide-necked aneurysms (technical note) J Neurosurg 86 724–727 Occurrence Handle9120640 Occurrence Handle1:STN:280:DyaK2s3jsVWmsw%3D%3D Occurrence Handle10.3171/jns.1997.86.4.0724

    Article  PubMed  CAS  Google Scholar 

  • J Moret C Cognard A Weill L Castaings A Rey (1997) ArticleTitleThe “remodeling technique” in the treatment of wide neck intracranial aneurysms Intervent Neuroradiol 3 21–35

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Rights and permissions

Reprints and permissions

About this article

Cite this article

Kwon, OK., Kim, S., Oh, C. et al. Embolization of wide-necked aneurysms with using three or more microcatheters. Acta Neurochir (Wien) 148, 1139–1145 (2006). https://doi.org/10.1007/s00701-006-0876-4

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s00701-006-0876-4

Navigation