Abstract
Flow diversion is a novel treatment for brain aneurysms that works by redirecting blood flow away from the aneurysm. Immediately after placement of the stent, blood flow stagnates within the aneurysm dome and it undergoes thrombosis. Over time, a new endothelium develops across the neck, thereby reconstructing the parent vessel and curing the aneurysm. The use of this treatment method for ruptured aneurysms has two specific concerns: 1) risk of hemorrhage from the aneurysm after treatment because of potential delayed aneurysm occlusion; and 2) hemorrhagic complications from antiplatelet use, which is required to prevent thromboembolic complications from the device. In this review, we explore these two concerns based on the emerging published literature. Optimal peri-procedural management of these issues in the neurocritical care setting is vital to improving outcomes. We also identify ongoing clinical trials of flow diversion for the treatment of ruptured aneurysms. Flow diversion is an alternative to clipping or coiling for many ruptured aneurysms and may be potentially more efficacious in certain aneurysm subtypes.
Similar content being viewed by others
References
Feigin VL, Lawes CM, Bennett DA, Barker-Collo SL, Parag V. Worldwide stroke incidence and early case fatality reported in 56 population-based studies: a systematic review. Lancet Neurol. 2009;8(4):355–69.
Griessenauer CJ, Ogilvy CS, Foreman PM, Chua MH, Harrigan MR, Stapleton CJ, Patel AB, He L, Fusco MR, Mocco J, Winkler PA, Patel AS, Thomas AJ. Pipeline embolization device for small paraophthalmic artery aneurysms with an emphasis on the anatomical relationship of ophthalmic artery origin and aneurysm. J Neurosurg. 2016. doi:10.3171/2015.12.JNS152499.
Stapleton CJ, Walcott BP, Fusco MR, Butler WE, Thomas AJ, Ogilvy CS. Surgical management of ruptured middle cerebral artery aneurysms with large intraparenchymal or sylvian fissure hematomas. Neurosurgery. 2015;76(3):258–64.
Kirkpatrick PJ, Turner CL, Smith C, Hutchinson PJ, Murray GD. Simvastatin in aneurysmal subarachnoid haemorrhage (STASH): a multicentre randomised phase 3 trial. Lancet Neurol. 2014;13(7):666–75.
Macdonald RL, Higashida RT, Keller E, Mayer SA, Molyneux A, Raabe A, Vajkoczy P, Wanke I, Bach D, Frey A. Clazosentan, an endothelin receptor antagonist, in patients with aneurysmal subarachnoid haemorrhage undergoing surgical clipping: a randomised, double-blind, placebo-controlled phase 3 trial (CONSCIOUS-2). Lancet Neurol. 2011;10(7):618–25.
Molyneux AJ, Birks J, Clarke A, Sneade M, Kerr RS. The durability of endovascular coiling versus neurosurgical clipping of ruptured cerebral aneurysms: 18 year follow-up of the UK cohort of the International Subarachnoid Aneurysm Trial (ISAT). Lancet. 2015;385(9969):691–7.
Spetzler RF, McDougall CG, Zabramski JM, Albuquerque FC, Hills NK, Russin JJ, Partovi S, Nakaji P, Wallace RC. The barrow ruptured aneurysm trial: 6-year results. J Neurosurg. 2015;123(3):609–17.
Petr O, Brinjikji W, Cloft H, Kallmes D, Lanzino G. Current trends and results of endovascular treatment of unruptured intracranial aneurysms at a single institution in the flow-diverter era. Am J Neuroradiol. 2016. doi:10.3174/ajnr.A4699.
Zhou G, Su M, Zhu YQ, Li MH. Efficacy of flow-diverting devices for cerebral aneurysms: a systematic review and meta-analysis. World Neurosurg. 2016;85:252–62. doi:10.1016/j.wneu.2015.09.088.
Brinjikji W, Murad MH, Lanzino G, Cloft HJ, Kallmes DF. Endovascular treatment of intracranial aneurysms with flow diverters a meta-analysis. Stroke. 2013;44(2):442–7.
Pierot L, Costalat V, Moret J, Szikora I, Klisch J, Herbreteau D, Holtmannspotter M, Weber W, Januel AC, Liebig T, Sychra V, Strasilla C, Cognard C, Bonafe A, Molyneux A, Byrne JV, Spelle L. Safety and efficacy of aneurysm treatment with WEB: results of the WEBCAST study. J Neurosurg. 2016;124(5):1250–6. doi:10.3171/2015.2.JNS142634.
Becske T, Kallmes DF, Saatci I, McDougall CG, Szikora I, Lanzino G, Moran CJ, Woo HH, Lopes DK, Berez AL, Cher DJ, Siddiqui AH, Levy EI, Albuquerque FC, Fiorella DJ, Berentei Z, Marosfoi M, Cekirge SH, Nelson PK. Pipeline for uncoilable or failed aneurysms: results from a multicenter clinical trial. Radiology. 2013;267(3):858–68. doi:10.1148/radiol.13120099.
Walcott BP, Pisapia JM, Nahed BV, Kahle KT, Ogilvy CS. Early experience with flow diverting endoluminal stents for the treatment of intracranial aneurysms. J Clin Neurosci. 2011;18(7):891–4. doi:10.1016/j.jocn.2011.01.002.
Walcott BP, Stapleton CJ, Choudhri O, Patel AB. Flow diversion for the treatment of intracranial aneurysms. JAMA Neurol. 2016;73(8):1002–8. doi:10.1001/jamaneurol.2016.0609.
Sundt TM Jr, Murphey F. Clip-grafts for aneurysm and small vessel surgery* part 3: clinical experience in intracranial internal carotid artery aneurysms. J Neurosurg. 1969;31(1):59–71.
Nakagawa F, Kobayashi S, Takemae T, Sugita K. Aneurysms protruding from the dorsal wall of the internal carotid artery. J Neurosurg. 1986;65(3):303–8.
Russin JJ, Kramer DR, Thomas D, Hasson D, Liu CY, Amar AP, Mack WJ, Giannotta SL. The importance of preoperative diagnosis of blister aneurysms. J Clin Neurosci. 2015;22(9):1408–12. doi:10.1016/j.jocn.2015.03.010.
Baskaya MK, Ahmed AS, Ates O, Niemann D. Surgical treatment of blood blister–like aneurysms of the supraclinoid internal carotid artery with extracranial–intracranial bypass and trapping. Neurosurg Focus. 2008;24(2):E13. doi:10.3171/FOC/2008/24/2/E13.
Kalani MYS, Zabramski JM, Kim LJ, Chowdhry SA, Mendes GA, Nakaji P, McDougall CG, Albuquerque FC, Spetzler RF. Long-term follow-up of blister aneurysms of the internal carotid artery. Neurosurgery. 2013;73(6):1026–33.
Park JH, In Sung P, Han DH, Kim SH, Oh CW, Kim J-E, Kim HJ, Han MH, Kwon O-K. Endovascular treatment of blood blister-like aneurysms of the internal carotid artery. J Neurosurg. 2007;106(5):812–9.
Gaughen J, Hasan D, Dumont A, Jensen M, Mckenzie J, Evans A. The efficacy of endovascular stenting in the treatment of supraclinoid internal carotid artery blister aneurysms using a stent-in-stent technique. Am J Neuroradiol. 2010;31(6):1132–8.
Lee B-H, Kim BM, Park MS, Park SI, Chung EC, Suh SH, Choi CS, Won YS, Yu IK. Reconstructive endovascular treatment of ruptured blood blister-like aneurysms of the internal carotid artery: clinical article. J Neurosurg. 2009;110(3):431–6.
Meckel S, Singh T, Undrén P, Ramgren B, Nilsson O, Phatouros C, McAuliffe W, Cronqvist M. Endovascular treatment using predominantly stent-assisted coil embolization and antiplatelet and anticoagulation management of ruptured blood blister–like aneurysms. Am J Neuroradiol. 2011;32(4):764–71.
Fiorella D, Albuquerque FC, Deshmukh VR, Woo HH, Rasmussen PA, Masaryk TJ, McDougall CG. Endovascular reconstruction with the Neuroform stent as monotherapy for the treatment of uncoilable intradural pseudoaneurysms. Neurosurgery. 2006;59(2):291–300.
Kulcsár Z, Wetzel SG, Augsburger L, Gruber A, Wanke I, Rüfenacht DA. Effect of flow diversion treatment on very small ruptured aneurysms. Neurosurgery. 2010;67(3):789–93.
McAuliffe W, Wenderoth J. Immediate and midterm results following treatment of recently ruptured intracranial aneurysms with the Pipeline embolization device. Am J Neuroradiol. 2012;33(3):487–93.
Martin AR, Cruz JP, Matouk CC, Spears J, Marotta TR. The pipeline flow-diverting stent for exclusion of ruptured intracranial aneurysms with difficult morphologies. Neurosurgery. 2012;70(1 Suppl Operative):21–8. doi:10.1227/NEU.0b013e3182315ee3 discussion 28.
Nerva JD, Morton RP, Levitt MR, Osbun JW, Ferreira MJ, Ghodke BV, Kim LJ. Pipeline embolization device as primary treatment for blister aneurysms and iatrogenic pseudoaneurysms of the internal carotid artery. J Neurointerv Surg. 2014;7:210–16. doi:10.1136/neurintsurg-2013-011047.
Chalouhi N, Zanaty M, Tjoumakaris S, Gonzalez LF, Hasan D, Kung D, Rosenwasser RH, Jabbour P. Treatment of blister-like aneurysms with the pipeline embolization device. Neurosurgery. 2014;74(5):527–32.
Yoon JW, Siddiqui AH, Dumont TM, Levy EI, Hopkins LN, Lanzino G, Lopes DK, Moftakhar R, Billingsley JT, Welch BG. Feasibility and safety of pipeline embolization device in patients with ruptured carotid blister aneurysms. Neurosurgery. 2014;75(4):419–29.
Linfante I, Mayich M, Sonig A, Fujimoto J, Siddiqui A, Dabus G. Flow diversion with Pipeline Embolic Device as treatment of subarachnoid hemorrhage secondary to blister aneurysms: dual-center experience and review of the literature. J NeuroInterv Surg. 2016. doi:10.1136/neurintsurg-2016-012287.
Kallmes DF, Hanel R, Lopes D, Boccardi E, Bonafe A, Cekirge S, Fiorella D, Jabbour P, Levy E, McDougall C, Siddiqui A, Szikora I, Woo H, Albuquerque F, Bozorgchami H, Dashti SR, Delgado Almandoz JE, Kelly ME, Rt Turner, Woodward BK, Brinjikji W, Lanzino G, Lylyk P. International retrospective study of the pipeline embolization device: a multicenter aneurysm treatment study. AJNR Am J Neuroradiol. 2015;36(1):108–15. doi:10.3174/ajnr.A4111.
Rouchaud A, Brinjikji W, Cloft H, Kallmes D. Endovascular treatment of ruptured blister-like aneurysms: a systematic review and meta-analysis with focus on deconstructive versus reconstructive and flow-diverter treatments. Am J Neuroradiol. 2015;36(12):2331–9.
Sughrue ME, Saloner D, Rayz VL, Lawton MT. Giant intracranial aneurysms: evolution of management in a contemporary surgical series. Neurosurgery. 2011;69(6):1261–70. doi:10.1227/NEU.0b013e31822bb8a6 discussion 1270–1261.
Hanel RA, Spetzler RF. Surgical treatment of complex intracranial aneurysms. Neurosurgery. 2008;62(6 Suppl 3):1289–97. doi:10.1227/01.neu.0000333794.13844.d9 discussion 1297–1289.
Ogilvy CS, Cheung AC, Mitha AP, Hoh BL, Carter BS. Outcomes for surgical and endovascular management of intracranial aneurysmsusing a comprehensive grading system. Neurosurgery. 2006;59(5):1037–43.
Sanai N, Zador Z, Lawton MT. Bypass surgery for complex brain aneurysms: an assessment of intracranial–intracranial bypass. Neurosurgery. 2009;65(4):670–83.
Kalani MYS, Zabramski JM, Hu YC, Spetzler RF. Extracranial-intracranial bypass and vessel occlusion for the treatment of unclippable giant middle cerebral artery aneurysms. Neurosurgery. 2013;72(3):428–36.
Kalani MYS, Ramey W, Albuquerque FC, McDougall CG, Nakaji P, Zabramski JM, Spetzler RF. Revascularization and aneurysm surgery: techniques, indications, and outcomes in the endovascular era. Neurosurgery. 2014;74(5):482–98.
Pisapia JM, Walcott BP, Nahed BV, Kahle KT, Ogilvy CS. Cerebral revascularization for the treatment of complex intracranial aneurysms of the posterior circulation: microsurgical anatomy, techniques and outcomes. J neurointerv surg. 2011;3(3):249–54.
Van Rooij W, Sluzewski M. Endovascular treatment of large and giant aneurysms. Am J Neuroradiol. 2009;30(1):12–8.
Molyneux AJ, Kerr RS, Yu L-M, Clarke M, Sneade M, Yarnold JA, Sandercock P, Group ISATC. International subarachnoid aneurysm trial (ISAT) of neurosurgical clipping versus endovascular coiling in 2143 patients with ruptured intracranial aneurysms: a randomised comparison of effects on survival, dependency, seizures, rebleeding, subgroups, and aneurysm occlusion. Lancet. 2005;366(9488):809–17.
Campi A, Ramzi N, Molyneux AJ, Summers PE, Kerr RS, Sneade M, Yarnold JA, Rischmiller J, Byrne JV. Retreatment of ruptured cerebral aneurysms in patients randomized by coiling or clipping in the International Subarachnoid Aneurysm Trial (ISAT). Stroke. 2007;38(5):1538–44.
Chalouhi N, Tjoumakaris S, Gonzalez LF, Dumont A, Starke R, Hasan D, Wu C, Singhal S, Moukarzel L, Rosenwasser R. Coiling of large and giant aneurysms: complications and long-term results of 334 cases. Am J Neuroradiol. 2014;35(3):546–52.
Shobayashi Y, Tateshima S, Kakizaki R, Sudo R, Tanishita K, Vinuela F. Intra-aneurysmal hemodynamic alterations by a self-expandable intracranial stent and flow diversion stent: high intra-aneurysmal pressure remains regardless of flow velocity reduction. J Neurointerv Surg. 2013;5(Suppl 3):iii38–42. doi:10.1136/neurintsurg-2012-010488.
Kulcsár Z, Houdart E, Bonafe A, Parker G, Millar J, Goddard A, Renowden S, Gal G, Turowski B, Mitchell K. Intra-aneurysmal thrombosis as a possible cause of delayed aneurysm rupture after flow-diversion treatment. Am j neuroradiol. 2011;32(1):20–5.
Cebral JR, Mut F, Raschi M, Scrivano E, Ceratto R, Lylyk P, Putman CM. Aneurysm rupture following treatment with flow-diverting stents: computational hemodynamics analysis of treatment. AJNR Am J Neuroradiol. 2011;32(1):27–33. doi:10.3174/ajnr.A2398.
Walcott BP, Reinshagen C, Stapleton CJ, Choudhri O, Rayz V, Saloner D, Lawton MT. Predictive modeling and in vivo assessment of cerebral blood flow in the management of complex cerebral aneurysms. J Cereb Blood Flow Metab. 2016;36(6):998–1003. doi:10.1177/0271678X16641125.
Lin N, Brouillard AM, Krishna C, Mokin M, Natarajan SK, Sonig A, Snyder KV, Levy EI, Siddiqui AH. Use of coils in conjunction with the Pipeline embolization device for treatment of intracranial aneurysms. Neurosurgery. 2015;76(2):142–9.
Park M, Kilburg C, Taussky P, Albuquerque F, Kallmes D, Levy E, Jabbour P, Szikora I, Boccardi E, Hanel R. Pipeline embolization device with or without adjunctive coil embolization: analysis of complications from the IntrePED Registry. Am J Neuroradiol. 2016;37:1127–31. doi:10.3174/ajnr.A4678.
Brinjikji W, Piano M, Fang S, Pero G, Kallmes DF, Quilici L, Valvassori L, Lozupone E, Cloft HJ, Boccardi E, Lanzino G. Treatment of ruptured complex and large/giant ruptured cerebral aneurysms by acute coiling followed by staged flow diversion. J Neurosurg. 2016;125(1):120–7. doi:10.3171/2015.6.JNS151038.
Pereira VM, Kelly M, Vega P, Murias E, Yilmaz H, Erceg G, Pellaton A, Lovblad KO, Krings T. New Pipeline Flex device: initial experience and technical nuances. J Neurointerv Surg. 2015;7(12):920–5. doi:10.1136/neurintsurg-2014-011347.
Le EJ, Miller T, Serulle Y, Shivashankar R, Jindal G, Gandhi D. Use of Pipeline Flex is associated with reduced fluoroscopy time, procedure time, and technical failure compared with the first-generation pipeline embolization device. J Neurointerv Surg. 2016. doi:10.1136/neurintsurg-2016-01226.
Whelan DM, van der Giessen WJ, Krabbendam SC, van Vliet EA, Verdouw PD, Serruys PW, van Beusekom HM. Biocompatibility of phosphorylcholine coated stents in normal porcine coronary arteries. Heart. 2000;83(3):338–45.
Kuiper KK, Robinson KA, Chronos NA, Cui J, Palmer SJ, Nordrehaug JE. Phosphorylcholine-coated metallic stents in rabbit iliac and porcine coronary arteries. Scand Cardiovasc J. 1998;32(5):261–8.
Girdhar G, Li J, Kostousov L, Wainwright J, Chandler WL. In-vitro thrombogenicity assessment of flow diversion and aneurysm bridging devices. J Thromb Thrombolysis. 2015;40(4):437–43. doi:10.1007/s11239-015-1228-0.
Ding Y, Lewis D, Kadirvel R, Dai D, Kallmes D. The Woven EndoBridge: a new aneurysm occlusion device. Am J Neuroradiol. 2011;32(3):607–11.
Spetzler RF, Hadley MN, Rigamonti D, Carter LP, Raudzens PA, Shedd SA, Wilkinson E. Aneurysms of the basilar artery treated with circulatory arrest, hypothermia, and barbiturate cerebral protection. J Neurosurg. 1988;68(6):868–79.
Henkes H, Fischer S, Mariushi W, Weber W, Liebig T, Miloslavski E, Brew S, Kühne D. Angiographic and clinical results in 316 coil-treated basilar artery bifurcation aneurysms. J Neurosurg. 2005;103(6):990–9.
Kelly ME, Turner R, Gonugunta V, Woo HH, Rasmussen PA, Masaryk TJ, Fiorella D. Stent reconstruction of wide-necked aneurysms across the circle of willis. Neurosurgery. 2007;61(5):249–55.
Lubicz B, Mine B, Collignon L, Brisbois D, Duckwiler G, Strother C. WEB device for endovascular treatment of wide-neck bifurcation aneurysms. Am J Neuroradiol. 2013;34(6):1209–14.
Pierot L, Liebig T, Sychra V, Kadziolka K, Dorn F, Strasilla C, Kabbasch C, Klisch J. Intrasaccular flow-disruption treatment of intracranial aneurysms: preliminary results of a multicenter clinical study. Am J Neuroradiol. 2012;33(7):1232–8.
Pierot L, Klisch J, Cognard C, Szikora I, Mine B, Kadziolka K, Sychra V, Gubucz I, Januel A-C, Lubicz B. Endovascular WEB flow disruption in middle cerebral artery aneurysms: preliminary feasibility, clinical, and anatomical results in a multicenter study. Neurosurgery. 2013;73(1):27–35.
Leon MB, Baim DS, Popma JJ, Gordon PC, Cutlip DE, Ho KK, Giambartolomei A, Diver DJ, Lasorda DM, Williams DO, Pocock SJ, Kuntz RE. A clinical trial comparing three antithrombotic-drug regimens after coronary-artery stenting. stent anticoagulation restenosis study investigators. N Engl J Med. 1998;339(23):1665–71. doi:10.1056/NEJM199812033392303.
Topol EJ, Investigators E. Randomised placebo-controlled and balloon-angioplasty-controlled trial to assess safety of coronary stenting with use of platelet glycoprotein-IIb/IIIa blockade. Lancet. 1998;352(9122):87–92.
Montalescot G, Wiviott SD, Braunwald E, Murphy SA, Gibson CM, McCabe CH, Antman EM, investigators T-T. Prasugrel compared with clopidogrel in patients undergoing percutaneous coronary intervention for ST-elevation myocardial infarction (TRITON-TIMI 38): double-blind, randomised controlled trial. Lancet. 2009;373(9665):723–31.
Brasiliense LB, Stanley MA, Grewal SS, Cloft HJ, Sauvageau E, Lanzino G, Miller D, Kallmes DF, Hanel R. Silent ischemic events after pipeline embolization device: a prospective evaluation with MR diffusion-weighted imaging. J Neurointerv Surg. 2016. doi:10.1136/neurintsurg-2015-012091.
Hoh BL, Nogueira RG, Ledezma CJ, Pryor JC, Ogilvy CS. Safety of heparinization for cerebral aneurysm coiling soon after external ventriculostomy drain placement. Neurosurgery. 2005;57(5):845–9.
Kung DK, Policeni BA, Capuano AW, Rossen JD, Jabbour PM, Torner JC, Howard MA III, Hasan D. Risk of ventriculostomy-related hemorrhage in patients with acutely ruptured aneurysms treated using stent-assisted coiling: clinical article. J Neurosurg. 2011;114(4):1021–7.
Kim DJ, Suh SH, Kim BM, Kim DI, Huh SK, Lee JW. Hemorrhagic complications related to the stent-remodeled coil embolization of intracranial aneurysms. Neurosurgery. 2010;67(1):73–8. doi:10.1227/01.NEU.0000370937.70207.95 discussion 78–79.
Amenta PS, Dalyai RT, Kung D, Toporowski A, Chandela S, Hasan D, Gonzalez LF, Dumont AS, Tjoumakaris SI, Rosenwasser RH, Maltenfort MG, Jabbour PM. Stent-assisted coiling of wide-necked aneurysms in the setting of acute subarachnoid hemorrhage: experience in 65 patients. Neurosurgery. 2012;70(6):1415–29. doi:10.1227/NEU.0b013e318246a4b1 discussion 1429.
Bodily KD, Cloft HJ, Lanzino G, Fiorella DJ, White PM, Kallmes DF. Stent-assisted coiling in acutely ruptured intracranial aneurysms: a qualitative, systematic review of the literature. AJNR Am J Neuroradiol. 2011;32(7):1232–6. doi:10.3174/ajnr.A2478.
Binz DD, Toussaint LG 3rd, Friedman JA. Hemorrhagic complications of ventriculostomy placement: a meta-analysis. Neurocrit Care. 2009;10(2):253–6. doi:10.1007/s12028-009-9193-0.
Bauer DF, Razdan SN, Bartolucci AA, Markert JM. Meta-analysis of hemorrhagic complications from ventriculostomy placement by neurosurgeons. Neurosurgery. 2011;69(2):255–60. doi:10.1227/NEU.0b013e31821a45ba.
Gardner PA, Engh J, Atteberry D, Moossy JJ. Hemorrhage rates after external ventricular drain placement: clinical article. J Neurosurg. 2009;110(5):1021–5.
Chalouhi N, Jabbour P, Singhal S, Drueding R, Starke RM, Dalyai RT, Tjoumakaris S, Gonzalez LF, Dumont AS, Rosenwasser R, Randazzo CG. Stent-assisted coiling of intracranial aneurysms: predictors of complications, recanalization, and outcome in 508 cases. Stroke. 2013;44(5):1348–53. doi:10.1161/STROKEAHA.111.000641.
Mega JL, Close SL, Wiviott SD, Shen L, Walker JR, Simon T, Antman EM, Braunwald E, Sabatine MS. Genetic variants in ABCB1 and CYP2C19 and cardiovascular outcomes after treatment with clopidogrel and prasugrel in the TRITON-TIMI 38 trial: a pharmacogenetic analysis. Lancet. 2010;376(9749):1312–9. doi:10.1016/S0140-6736(10)61273-1.
Author Contribution
All authors made a substantial contribution to the concept and design, acquisition of data or analysis and interpretation of data, drafted the article or revised it critically for important intellectual content, and approved the version to be published.
Author information
Authors and Affiliations
Corresponding author
Ethics declarations
Conflict of interest
ABP is a paid consultant for Penumbra and Covidien.
Rights and permissions
About this article
Cite this article
Walcott, B.P., Koch, M.J., Stapleton, C.J. et al. Blood Flow Diversion as a Primary Treatment Method for Ruptured Brain Aneurysms—Concerns, Controversy, and Future Directions. Neurocrit Care 26, 465–473 (2017). https://doi.org/10.1007/s12028-016-0318-y
Published:
Issue Date:
DOI: https://doi.org/10.1007/s12028-016-0318-y