The hemodynamic alterations induced by the vascular angular deformation in stent-assisted coiling of bifurcation aneurysms

https://doi.org/10.1016/j.compbiomed.2014.07.006Get rights and content

Highlights

  • The hemodynamic changes induced by vascular remodeling were investigated.

  • The intra-aneurysmal flow activity was reduced by stent-induced vessel deformation.

  • The maximum wall shear stress and oscillatory shear index were also increased.

  • Bifurcation angle remodeling provided an unfavorable hemodynamic environment.

Abstract

The hemodynamic changes induced by stent deployment and vascular remodeling in bifurcation aneurysms were investigated using computational fluid dynamics. The stent deployment reduced the intra-aneurysmal flow activity by decreasing the mean velocity, mean kinetic energy, mean wall shear stress, and mean vorticity. These hemodynamic parameters increased with an increase in the branching angle because of the vessel deformation caused by stent straightening. The maximum wall shear stress and its spatial gradient occurred near the neck of the aneurysm in the stented left daughter vessel, whereas a maximum oscillatory shear index was detected near the neck of the right aneurysm of the right daughter vessel. Theses parameters, which might be related to the recurrence of aneurysms, were also increased by stent-induced vessel deformation.

Introduction

An intracranial aneurysm is a cerebrovascular disorder in which the arterial wall weakens—resulting in localized dilation. Rupture of aneurysms causes sub-arachnoid hemorrhages, which are associated with high mortality and morbidity [1], [2], [3]. Interventional thromboembolization by endovascular insertion of coils is currently the most popular treatment to prevent the rupture of aneurysms. Thin platinum coils are inserted into the aneurysmal sac, where they form a thrombus that obliterates the aneurysm. Coil embolization of a wide neck aneurysm can be challenging and may not be effective [4] because of coil herniation. In recent years, stent-assisted coil embolization—in which the flexible stent acts as a supporting bridge to prevent herniation of aneurysm coils—has been widely used. The stent can divert flow into the aneurysmal sac and prevent coil herniation; therefore, stent-assisted coil embolization promotes the occlusion of incompletely coiled aneurysms and lowers the risk of recanalization compared with non-stenting embolization [5], [6], [7], [8], [9]. Various stent configurations have been used for bifurcation aneurysms [10], and deployment of a flexible stent may deform the host artery because of the mechanical interaction between stent and vessel. The bifurcation angle remodeling associated with stent placement has been investigated in the carotid arteries [11], anterior communicating arteries [12], and intracranial arteries [13]. The immediate and delayed angular remodeling after stent deployment can affect thromboembolization efficacy and aneurysm recurrence because alterations of the vessel bifurcation geometry can alter the hemodynamics in aneurysms.

Computational and experimental studies have been conducted using idealized or patient-specific models to investigate the intra-aneurysmal hemodynamic changes caused by stents [10], [14], [15], [16], [17], [18], [19], [20], [21]. Meng et al. [17] and Wang et al. [21] investigated the hemodynamic alterations in idealized saccular aneurysm models—side wall and terminal aneurysm models—before and after stent placement using computational fluid dynamic (CFD) methods. Canton et al. [15] measured changes in flow dynamics using particle image velocimetry in bifurcating cerebral aneurysm models after a Neuroform® stent placement and concluded that the magnitude of the velocity of the jet entering the sac was reduced by up to 11%. Tateshima et al. [20] studied the hemodynamic effect of Neuroform® stent placement across the necks of patient-specific aneurysm models and concluded that the stents significantly altered flow velocity and flow structure in aneurysms. Tang et al. [19] studied the hemodynamic effects of aneurysm neck size after stenting and concluded that the volume flow rate of blood entering the aneurysm over the entire cardiac cycle could be reduced by >50% after the endovascular operation. Most of these studies focused on the intra-aneurysmal hemodynamic changes caused by the inserted stent; however, the hemodynamic alterations caused by vessel deformation after stenting—which may affect the efficacy of thromboembolization and recurrence of aneurysms—have not been studied to date.

Recently, using patient-specific CFD analysis, Gao et al. [22], [23] observed significant hemodynamic alterations near the neck of an intracranial bifurcation aneurysm caused by stent-induced angular remodeling. The authors virtually removed the aneurysm by using an aneurysm-capping method and showed that stent-induced angular remodeling resulted in the migration and narrowing of the flow impingement zone and a decrease in apical pressure. Given that the CFD study focused on the hemodynamic changes in completely thromboembolized aneurysms after long-term remodeling of stented aneurysms, it did not consider the deployed stent and coils inside an aneurysmal sac, which can have a significant influence on intra-aneurysmal hemodynamics. The immediate vascular remodeling caused by straightening of a stent after stent-assisted coiling treatment may affect the efficacy of thrombus formation inside the aneurysmal sac. However, the intra-aneurysmal hemodynamic changes caused by vascular deformation have not been investigated. In the present study, we have modeled a deployed stent and coils inside an aneurysmal sac of the basilar bifurcation arteries, and investigated the hemodynamic changes induced by the angular deformation caused by straightening of the stent; the hemodynamic parameters in the wide neck aneurysms were computed, and the effect of bifurcation angle remodeling on the effectiveness of aneurysm embolization was discussed.

Section snippets

Aneurysm and stent modeling

Two wide neck aneurysms located at the tip of a basilar arterial bifurcation were constructed using solid modeling software (SolidWorks, Dassault Systems, Concord, NH) to simulate a terminal aneurysm occurring at the tip of a basilar arterial bifurcation. The present study used 2 idealized aneurysm models. The wide neck basilar aneurysms from the patient angiograms were idealized as half-sphere aneurysms occurring at the tip of the symmetric Y-bifurcations. The aneurysm diameter, basilar artery

Results

The effectiveness of thromboembolization by insertion of a stent and coils was estimated by examining the reduction in intra-aneurysmal flow activity. Both MVE and MKE were reduced by insertion of a stent, which showed a flow diversion effect of a stent in the small and medium aneurysm models (Fig. 3). The percent reductions of MVE and MKE were 8.2% and 12.7%, respectively, for a small aneurysm model, and 7.9% and 13.1%, respectively, for a medium aneurysm model. The MVE and MKE increased by

Discussion

Stent-assisted coil embolization has been successfully used in the treatment of intracranial aneurysms, and Y-stenting has been frequently used to treat wide neck aneurysms at arterial bifurcations [24]. Stent placement prevents coil protrusion into the parent artery, with the additional inflow blocking effects of the flow diversion. Once a stent is deployed inside an artery, a self-expanding stent exerts a force that resists bending, as confirmed by the bifurcation angular changes observed

Summary

Stent-assisted coil embolization is used for the treatment of wide neck aneurysms to prevent coil herniation into the parent arteries. A self-expanding stent causes immediate and delayed angular remodeling of the arteries, which may affect thromboembolization efficacy and aneurysm recurrence. Computational flow dynamics analysis was performed using coiled basilar tip aneurysm models to elucidate the hemodynamic alterations caused by stenting and stent-induced vessel deformation. The hemodynamic

Conflict of interest statement

None

Source of funding

The present study was supported by the 2014 Research Fund at Myongji University.

Ethical Approval: No human subjects were involved in the present study.

Acknowledgment

This work was supported by 2014 Research Fund of Myongji University.

References (61)

  • M.H. Babiker et al.

    J. Biomech.

    (2012)
  • T.-M. Liou et al.

    J. Biomech.

    (2008)
  • M. Tremmel et al.

    World Neurosurg.

    (2010)
  • I. Larrabide et al.

    Med. Image Anal.

    (2012)
  • R. Ouared et al.

    Comput. Phys. Commun.

    (2008)
  • A. Tippe et al.

    Thrombus Res.

    (1993)
  • S. Cito et al.

    Thrombus Res.

    (2013)
  • K. Hayashi et al.

    J. Biomech.

    (1980)
  • R. Torii et al.

    Comput. Fluids

    (2007)
  • Y. Shobayashi et al.

    Med. Eng. Phys.

    (2010)
  • W. Wu et al.

    J. Biomech.

    (2007)
  • M. Kaminogo et al.

    Stroke

    (2003)
  • F. Linn et al.

    Stroke

    (1996)
  • H.R. Winn et al.

    J. Neurosurg.

    (2002)
  • M. Hayakawa et al.

    J. Neurosurg.

    (2000)
  • N. Chalouhi et al.

    Neurosurgery

    (2012)
  • B. Izar et al.

    PloS One

    (2011)
  • M.F. Lawson et al.

    Neurosurgery

    (2011)
  • M. Piotin et al.

    Stroke

    (2010)
  • A. Wakhloo et al.

    Am. J. Neuroradiol.

    (2012)
  • J. Berkefeld et al.

    Neuroradiology

    (2002)
  • Q.-H. Huang et al.

    Am. J. Neuroradiol.

    (2011)
  • B. Gao et al.

    Am. J. Neuroradiol.

    (2012)
  • S. Appanaboyina et al.

    Int. J. Comput. Fluid Dyn.

    (2008)
  • G. Cantón et al.

    J. Neurosurg.

    (2005)
  • F. Dorn et al.

    Neuroradiology

    (2011)
  • H. Meng et al.

    Am. J. Neuroradiol.

    (2006)
  • G. Mulder et al.

    J. Eng. Math.

    (2009)
  • A.Y.-S. Tang et al.

    J. Biomed. Sci. Eng.

    (2012)
  • S. Tateshima et al.

    J. Neurosurg.

    (2009)
  • Cited by (27)

    • Risk factors for the rupture of mirror middle cerebral artery aneurysm using computer-assisted semiautomated measurement and hemodynamic analysis

      2022, Journal of Stroke and Cerebrovascular Diseases
      Citation Excerpt :

      The number of finite-volume grid elements used in this study was approximately 1 million. After mesh generation, the vascular model and blood flow state were generated using the following assumptions: the vascular wall was rigid, and the blood flow was isothermal and laminar (an incompressible Newtonian fluid).15 The blood flow was approximated using the unsteady Navier-Stokes equations.

    • Stent-induced vessel deformation after intracranial aneurysm treatment – A hemodynamic pilot study

      2019, Computers in Biology and Medicine
      Citation Excerpt :

      These coils were not explicitly resolved in the simulation due to the unknown and random location of the single wires. Instead, the theory of porous media was applied to mimic their effect on the hemodynamics [17]. The coil volume divided by the aneurysm volume gives the packing density.

    • Influence of aging-induced flow waveform variation on hemodynamics in aneurysms present at the internal carotid artery: A computational model-based study

      2018, Computers in Biology and Medicine
      Citation Excerpt :

      To address the issue, a basic step is to quantitatively evaluate the relationship between intra-aneurysmal hemodynamic parameters and the characteristics of flow waveform, which is however challenging for clinical studies due to the limited temporal/spatial resolutions of hemodynamic measurement techniques available in general clinical settings. As an alternative approach, computational fluid dynamics (CFD) simulations have been widely employed to quantify hemodynamic parameters in cerebral aneurysms [21–27]. In the present study, we performed hemodynamic simulations on 26 ICA aneurysms using two typical flow waveforms measured in young and older adults respectively, aiming to elucidate how aging-related flow waveform variation affects the characteristics of intra-aneurysmal flow patterns.

    View all citing articles on Scopus
    View full text