Towards the Clinical utility of CFD for assessment of intracranial aneurysm rupture–a systematic review and novel parameter-ranking tool

L Liang, DA Steinman, O Brina, C Chnafa… - Journal of …, 2019 - jnis.bmj.com
Background Intracranial aneurysms (IAs) are vascular dilations on cerebral vessels that
affect between 1%–5% of the general population, and can cause life-threatening intracranial …

Multiple aneurysms anatomy challenge 2018 (MATCH): phase I: segmentation

P Berg, S Voß, S Saalfeld, G Janiga… - Cardiovascular …, 2018 - Springer
Purpose Advanced morphology analysis and image-based hemodynamic simulations are
increasingly used to assess the rupture risk of intracranial aneurysms (IAs). However, the …

Multiple Aneurysms AnaTomy CHallenge 2018 (MATCH)—phase II: rupture risk assessment

P Berg, S Voß, G Janiga, S Saalfeld… - International journal of …, 2019 - Springer
Purpose Assessing the rupture probability of intracranial aneurysms (IAs) remains
challenging. Therefore, hemodynamic simulations are increasingly applied toward …

Feasibility of robot-assisted neuroendovascular procedures

VM Pereira, P Nicholson, NM Cancelliere… - Journal of …, 2021 - thejns.org
OBJECTIVE Geographic factors prevent equitable access to urgent advanced
neuroendovascular treatments. Robotic technologies may enable remote endovascular …

Evaluation of effectiveness and safety of the CorPath GRX robotic system in endovascular embolization procedures of cerebral aneurysms

VM Pereira, H Rice, L De Villiers, N Sourour… - Journal of …, 2024 - jnis.bmj.com
Background Robotic-assisted neurointervention was recently introduced, with implications
that it could be used to treat neurovascular diseases. Objective To evaluate the effectiveness …

[HTML][HTML] Novel flat-panel cone-beam CT compared to multi-detector CT for assessment of acute ischemic stroke: a prospective study

P Nicholson, NM Cancelliere, J Bracken… - European Journal of …, 2021 - Elsevier
Abstract Purpose Cone beam CT (CBCT) imaging assessment of acute ischemic stroke
(AIS) patients with large-vessel occlusion (LVO) in the angiosuite may improve stroke …

How patient-specific do internal carotid artery inflow rates need to be for computational fluid dynamics of cerebral aneurysms?

M Najafi, NM Cancelliere, O Brina, P Bouillot… - Journal of …, 2021 - jnis.bmj.com
Background Computational fluid dynamics (CFD) has become a popular tool for studying
'patient-specific'blood flow dynamics in cerebral aneurysms; however, rarely are the inflow …

Sensitivity of hostile hemodynamics to aneurysm geometry via unsupervised shape interpolation

DE MacDonald, NM Cancelliere, VM Pereira… - Computer Methods and …, 2023 - Elsevier
Abstract Background and Objective Vessel geometry and hemodynamics are intrinsically
linked, whereby geometry determines hemodynamics, and hemodynamics influence …

4D-CT angiography versus 3D-rotational angiography as the imaging modality for computational fluid dynamics of cerebral aneurysms

NM Cancelliere, M Najafi, O Brina, P Bouillot… - Journal of …, 2020 - jnis.bmj.com
Background and purpose Computational fluid dynamics (CFD) can provide valuable
information regarding intracranial hemodynamics. Patient-specific models can be …

Neurohumoral integration of cardiovascular function by the lamina terminalis

NM Cancelliere, EAE Black, AV Ferguson - Current hypertension reports, 2015 - Springer
The mechanisms involved in cardiovascular regulation, such as vascular tone, fluid volume
and blood osmolarity, are quite often mediated by signals circulating in the periphery, such …